Construction types ISOTOP

  • MSN
  • SD
  • DSD
  • BL
  • MSN/Z / SD/Z
  • DZE
  • FP / FPK

ISOTOP® MSN elements have a resonant frequency up to 3,2 Hz, depending on the load and are mainly used for: Compressors, Extractors, Small ventilators, Small fans, Audio loud speaker,s Pumps, Emergency power units.

Advantages

  • Low construction height
  • Low resonant frequency
  • Construction height, diameter and connection thread are identical for all types which guarantees exchangeability
  • Condition of spring elements is clearly visible due to the open construction
  • No condensing
  • Durable, compact design

ISOTOP® MSN
 All metal steel spring vibration isolators - MSN

ISOTOP® SD steel spring vibration isolators have a resonant frequency of about 3 Hz 180 min-1 and are used for: Source isolation of ventilators, fans, extractors, air conditioners, compressors, emergency power units, pumps, etc. Receiver isolation of sensitive electronic assemblies, measuring equipment, scales, test beds, etc. Percussion isolation of all sorts of machines.

Advantages

  • Construction height, diameter and connection thread are identical for all types, which guarantees exchangeability.
  • As a result of the open construction, the source is connected to the foundation point only via the spring.
  • The spring element can oscillate in the horizontal plane without restriction.
  • The spring is clearly visible, which allows checking of its condition without dismantling.
  • The distance between spring coils is visible under load.
  • Accessories, base plate and height adjustment are universally applicable for all types.

ISOTOP® SD
Steel spring vibration damper - SD

ISOTOP® DSD steel spring vibration isolators are used for source and receiver isolation of all impact type machines, as well as for machines of which the operating point is within the resonance range or which can start rocking when traversing the resonance. Examples: Block-type thermal power stations, Compressors, Rotating machines, motors, turbines Mobile equipment, emergency power units, Centrifuges, pumps Plan tables, test beds, scales Vibrating tables, conveyors, Transport storage of delicate goods.

Advantages

  • Construction height, diameter and connection thread are identical for all types, which guarantees exchangeability.
  • As a result of the open construction, the source is connected to the foundation point only via the spring. The spring element can oscillate in the horizontal plane without restriction.
  • The spring is clearly visible, which allows checking of its condition without dismantling. The distance between spring coils is visible under load.
  • Accessories, base plate and height adjustment are universally applicable for all types.
  • The damping core is permanently elastic and break-proof
  • High corrosion resistance is accomplished with cataphoresis coating

ISOTOP® DSD
Steel spring oscillation isolators with integrated high-performance damping element

ISOTOP® BL block elements have a resonant frequency up to 3,2 HZ, depending on the load. Due to the low construction height they are ideal for applications with limited available space like for example: Source isolation of heavy ventilators, fans, extractors, air conditioners, compressors, emergency power units, pumps, textile machinery, presses, etc. Receiver isolation of sensitive measuring equipment, scales, test beds, control cabinets, transport bearing etc. Vibration isolation of all kinds.

Advantages

  • Construction height is identical for all types, which guarantees exchangeability.
  • As a result of the open construction, the source is connected to the suspension point only via the spring. The spring element can oscillate in the horizontal plane without restriction.
  • The spring is clearly visible, which allows checking of its condition without dismantling. The distance between spring coils is visible under load.
  • The form of the steel plates can be adapted to connecting surfaces.
  • ISOTOP® BL/DSD elements have got a defined static and dynamic rigidity and damping. High precision of manufacture guarantees that no dimensional deviations or deviation of technical parameters results.

ISOTOP® MSN-BL
Flat block elements for smaller loads and limited space - MSN-BL
ISOTOP® BL
Spring block elements - BL
ISOTOP® BL/DSD
Block elements with attenuators for heavy loads

ISOTOP® tension elements have a resonant frequency of about 3 Hz 180 min-1 and are used for: Suspension elements from ceilings and steel constructions. Source isolation of ceiling-hung ventilators, fans, extractors, air conditioners, pipe lines, etc. Receiver isolation of sensitive electronic measuring equipment in refrigeration, air conditioning and ventilation as well as in pipe line and ceiling construction. Percussion isolation of all sorts of machines.

Advantages

  • Element dimensions and connecting threads of the elements within the type series MSN/Z or SD/Z are uniform, which guarantees exchangeability.
  • As a result of the open construction of the spring elements, the source is connected to the suspension point only via the spring. The spring element can oscillate in the horizontal plane without restriction.
  • The spring is clearly visible, which allows checking of its condition without dismantling. The distance between spring coils is visible under load.

ISOTOP® MSN / Z and SD / Z
Steel spring vibration damper tension elements - MSN / Z and SD / Z

ISOTOP® DZE elements can be adjusted individually up to a resonance frequency of approx. 7 Hz, depending on the load and disturbance frequency. Various applications, for example elastic isolation of: Compressors, Pumps, Cooling towers, Fast rotating machines, HVAC Roof-top devices, Emergency power units, Vibration isolation of all kinds.

Advantages

  • Different combinations of spring/damper elements depending on the load of the device allow ideal frequency tuning.
  • Premounted elements ensure fast assemblage
  • Demolition-proof – especially advisable for narrow and tall devices or mobile applications
  • Long durability
  • Low resonant frequency
  • Low construction height

ISOTOP® DZE
Multi-part element DZE

ISOTOP® FP base plates are an essential element for fixing the ISOTOP® DSD steel spring vibration isolators of the series SD and DSD to the base, the intermediate floors or the block foundation. ISOTOP® FP/K structure-borne noise damped base plates have a resonant frequency of 15 - 30 Hz 900 - 1800 min-1 and are used in conjunction with ISOTOP® DSD steel spring vibration isolators of the series SD and DSD for the separation of structure-borne noise.

Advantages

  • Construction height, diameter and connection thread are identical for all types, which guarantees exchangeability.
  • For ISOTOP® FP/K structure borne noise damped base plates no transfer of structure borne noise results from the base plate via the securing bolts to the foundation.

ISOTOP® FP
Structure-borne damped base plates - FP / K

 

Enquiry form